Product Description
TC-5063A, Pneumatic UHF TEM Cell generates the Electro-Magnetic
field for testing small RF devices such as wireless pager, GPS
Receiver, Mobile phone, etc. An external test signal applied
through the input port of the TC-5063A generates a consistent and
predictable TEM test field inside the cell.
The radiation field from a device transmitting in the Cell can
also be detected through the port using a test receiver. The
unique compact and economical design is optimized for medium
accuracy measurements beyond the standard TEM Cell frequency
range.
Theory of Operation
TC-5063A UHF TEM Cell cell is made to work beyond
the typical TEM Cell operating frequency range limited by cell resonance.
A typical TEM Cell is a 2-port symmetrical device; RF voltage is applied
to one port while the other port is terminated in 50 ohm while maintaining
50 ohm characteristic impedance along the cell. Due to expansion and
contraction of parts of the cell, the wave propagation beyond certain
frequency is no more propagated by TEM mode alone and creates resonance.
To eliminate the resonance problem, the half of the cell is
replaced by the wave absorbing material. One commercial implementation
is a G-TEM cell. The size of a G-TEM design is too large for typical
small device applications due to the type of absorber used.
We borrowed the concept of the G-TEM, but changed the termination
implementation scheme, and designed a very compact broad band TEM
Cell that can be used on a desktop.
The operation principle of TC-5063A is
essentially the same as TEM Cell. The E-H field inside the test
volume is proportional to the input voltage and inversely
proportional to the cell height.
If a radiating object is inserted inside the cell, the radiated wave
toward input port is guided by the transmission line and picked up
at the input with a receiver such as a spectrum analyzer. With this
method, the RFI from a radiating Device can be measured quantitatively.
Since this apparatus is very broadband, it has many applications in
the area of EMI, EMS, receiver sensitivity test, etc.
Key Features
- Radiation and susceptibility test
- A broadband TEM Cell up to 3GHz
- Small size, Small footprint for desktop applications
- High effective shielding
- Specifically designed for various types of mobile phones
- Pneumatic Open / Close Construction
- RS-232C Open / Close control
Applications
- Receiver sensitivity testing, Transmitter radiated power testing
- EMI and EMS tests for small UHF devices
- Mobile Phone, WLAN, PDA, Bluetooth, DAB/DMB

Specifications